Industrial Cameras FAQ/Camera outputs no signal to DI...

Camera outputs no signal to DIO(GPIO) pin. (No.298)

In some BU series camera, I/O mode factory setting of DIO(GPIO) line has been changed to input mode.

If user application handles DIO(GPIO) lines as output line without setting Line I/O mode register to output mode, the camera may not output signal from DIO(GPIO) line.

User application should set Line I/O mode to output mode using SetCamLineModeAll() or GenICam functions before handling DIO(GPIO) lines as output port. Bit0 (1), bit1 (2), and bit2 (4) in LineModeAll register correspond to I/O mode of Line 0 (External Trigger Input), Line 1, and Line 2.

For example, when LineModeAll register value is 2, Line 1 is output mode, Line 0 and Line 2 are input mode.

Note that there are camera models whose I/O mode of DIO(GPIO) lines are fixed. Please check instruction manual of the camera about I/O mode of DIO(GPIO) line.

back

Was this FAQ helpful?

Please let us know your opinion about the FAQ so that we will be able to improve our FAQ. (Within 800 characters)
Note: If you need a reply to your inquiry (e.g. inquiry about products), please use the inquiries form provided on Contact Us page. Please note that we cannot answer to your questions filled in below.