Industrial Cameras FAQ/When acquiring images in softw...

When acquiring images in software trigger mode, is it necessary to start and stop the stream each time acquiring a single image?(No.295)

After opening and starting stream, you can issue the software trigger command any number of times, one image is taken each time a software trigger command is issued.

The camera does not accept the next software trigger command while the camera is performing the imaging acquisition receiving a software trigger command.

Issue software trigger command after receiving the image being acquiring, or issue software trigger command after the FrameTriggerWait event became active.